Brivis Wombat 92 (pre electronic) installed inside roof. Good access. Please quote to replace VR800A-1160 gas valve. Quote separately for parts & labour.
Main burner does not come on. No smell of gas, valve doesn't seem to open. Pilot is lit & maintaining. Room thermostat signal reaching unit (multimeter check). Overheat switch ok, not tripped. Fan works when manual override pressed. Suspect fault in Honeywell VR800A-1160 gas valve.